戴国亮, 曹小林, 龚维明. Analysis of Bearing Capacity of FRPC Pipe as Energy Storage Medium under the Action of Compressed Air[J]. 2019, 39(4): 579-584+591. DOI: 10.13409/j.cnki.jdpme.2019.04.006.
Analysis of Bearing Capacity of FRPC Pipe as Energy Storage Medium under the Action of Compressed Air
Renewable energy storage system uses reinforced concrete pile foundation to store renewable energy generated by solar panels.The renewable energy is stored in the hollow section of pile foundation in the form of compressed air.The pile foundation
acting as a load-bearing structure of the upper structure
sustains not only the upper structure load
but also the soil reaction force and the compressed air pressure.However
concrete is prone to cracking under tensile stress
which leads to the limitation of energy storage performance and durability of reinforced concrete piles.In order to overcome these defects of traditional reinforced concrete energy piles
this paper studies the dual functions of various FRP(Fiber Reinforced Polymer)-concrete composite pile foundations as energy storage and load bearing structures.Considering the combined action of structural load
soil reaction and internal air pressure caused by compressed air thermodynamic circulation
the applicability of multiple forms of composite energy pile foundation system is analyzed by the finite element method.The study shows that the inner and outer FRP pipes can effectively improve the service performance and durability of piles
and the service reliability and durability of FRPC pipe piles are improved compared with that of reinforced concrete piles.
The role of compressed air energy storage (CAES) in future sustainable energy systems [J] . Henrik Lund,Georges Salgi. Energy Conversion and Management . 2009 (5)
Application of FRP composites for underwater piles repair [J] . Rajan Sen,Gray Mullins. Composites Part B . 2006 (5)
Underwater Fiber–Reinforced Polymers Repair of Prestressed Piles in the Allen Creek Bridge [J] . Gray Mullins,Rajan Sen,Kwangsuk Suh,Danny Winters. Journal of Composites for Construction . 2005 (2)
Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Experimental Investigation [J] . Amir Fam,David Schnerch,Sami Rizkalla. Journal of Composites for Construction . 2005 (1)
Drivability of Glass FRP Composite Piling [J] . Scott A. Ashford,Warrasak Jakrapiyanun. Journal of Composites for Construction . 2001 (1)