Study on the Hysteretic Behavior of Side Plate Reinforced Beam-to-column Connections in Steel Frame
This paper puts forward an improved side plate reinforced beam-to-column connection.The reinforced plate is composed of two rectangular column side plates and four right angle trapezoid beam side plates.Based on the existing experiment of beam flange side plate reinforced joints
the finite element software ABAQUS was used to simulate the cyclic performance of the improved side plate reinforced beam-to-column connection for 11 models with different part-dimensions.Results showed that under the cyclic loading
the buckling deformation did not formed in the beam section at the end of the reinforced plate in the joint model reinforced by two small rectangular column side plates
while the stress concentration decreased in the beam section at the end of the reinforced plate
and the plastic deformation still concentrated on the panel zone of the column web.After replacing the two small rectangular column side plates with a large column side plate
the bearing capacity of the connection improved substantially
and the plastic deformation concentrated on the beam section at the end of the beam side plate.The panel zone was now in an elastic state.It indicated that the reinforced technique accords with the seismic design principle of "strong joint and weak member".Some suggestions for side plate design were presented.The column side plate was recommended to extend out 50 mm from the column flange surface.The height of the column side plate should be equal to the height of the beam section.The thickness of the column side plate could be 6 mm.The lateral edges of the beam side plate are suggested to reach the edges of the column flange.The ratio of the length to width of the end triangle plate could be 1∶2-1∶3
and the length of the rectangle of the beam side plate could be the same as or slightly larger than that of the triangle is recommended.
Seismic performance of steel beam-to-column moment connections with tapered beam flanges [J] . Cheng-Chih Chen,Chun-Chou Lin. Engineering Structures . 2013
Ductile moment connections used in steel column-tree moment-resisting frames [J] . Cheng-Chih Chen,Chun-Chou Lin,Chieh-Hsiang Lin. Journal of Constructional Steel Research . 2005 (8)
Parametric study and design of rib-reinforced steel moment connections [J] . Cheng-Chih Chen,Cheng-An Lu,Chun-Chou Lin. Engineering Structures . 2005 (5)
Through-Thickness Properties of Column Flanges in Welded Moment Connections [J] . Robert J. Dexter,Minerva I. Melendrez. Journal of Structural Engineering . 2000 (1)
Lessons from damage to steel buildings during the Northridge earthquake [J] . Stephen A. Mahin. Engineering Structures . 1997 (4)
Lessons learned from the Northridge earthquake [J] . Duane K. Miller. Engineering Structures . 1997 (4)