西南交通大学机械工程学院,四川 成都,610031
周旭(1996—),男,博士。主要从事能源地下结构研究。E-mail:zhouyi27@my.swjtu.edu.cn
曹晓玲(1984—),女,高级工程师,硕导,博士。主要从事地下能源结构及能源系统研究。Email:xlcao@swjtu.edu.cn
收稿:2023-09-27,
修回:2023-12-26,
纸质出版:2024-08-30
移动端阅览
周旭,吴浪,曹晓玲等.能源连续墙对室内侧壁面热湿耦合传递行为的影响[J].防灾减灾工程学报,2024,44(04):893-900.
ZHOU Xu,WU Lang,CAO Xiaoling,et al.Effect of Energy Diaphragm Wall on the Coupled Heat and Moisture Transfer Behavior of Interior Side Walls[J].Journal of Disaster Prevention and Mitigation Engineering,2024,44(04):893-900.
周旭,吴浪,曹晓玲等.能源连续墙对室内侧壁面热湿耦合传递行为的影响[J].防灾减灾工程学报,2024,44(04):893-900. DOI: 10.13409/j.cnki.jdpme.20230927013.
ZHOU Xu,WU Lang,CAO Xiaoling,et al.Effect of Energy Diaphragm Wall on the Coupled Heat and Moisture Transfer Behavior of Interior Side Walls[J].Journal of Disaster Prevention and Mitigation Engineering,2024,44(04):893-900. DOI: 10.13409/j.cnki.jdpme.20230927013.
目前国内外针对能源连续墙的研究主要集热交换性能,鲜有研究关注其对邻近地下建筑热湿环境的影响。本文通过建立热湿耦合传递三维数值模型,研究了能源连续墙对相邻地下室墙体壁面热湿状态和与室内环境热湿交互通量的影响。研究结果表明,能源连续墙的运行明显改变了室内侧壁面的热湿流方向和热湿流密度大小;与纯传热结果相比,虽然传湿过程对壁面温度的影响小于0.2 ℃,但是这部分差异会造成显热热流密度预测偏差超过10%;不计潜热热流会造成对地下室内热负荷的低估超过2.4%;绝缘层的隔热防潮作用能够阻碍流向室内的热量和湿汽。
Current research on Energy Diaphragm Walls (EDWs)
both domestically and internationally
mainly focuses on heat exchange performance
with few studies addressing their impact on the thermal and moisture environment of adjacent underground buildings. This paper investigates the influence of EDWs on the heat and moisture conditions of adjacent basement walls and the heat and moisture flux interaction with the indoor environment by establishing a 3D numerical model of coupled heat and moisture transfer. Results showed that the operation of the EDWs significantly changed the direction and intensity of heat and moisture flow on the interior side walls. Although the impact of the moisture transfer process on wall temperature change was less than 0.2℃ compared to pure heat transfer results
this small discrepancy can cause a prediction deviation of sensible heat flux density by more than 10%. Ignoring the latent heat flux can result in an underestimation of the total thermal load of the underground space by more than 2.4%. Moreover
the insulation layer effectively blocks the flux of heat and moisture into the indoor environment.
Cao X , Yuan Y P , Sun L L . Restoration performance of vertical ground heat exchanger with various intermittent ratios [J]. Geothermics , 2015 , 54 : 115 - 121 .
郑秀玲 , 刘耶军 . 地源热泵系统优化控制的综述 [J]. 福建茶叶 , 2020 , 42 ( 2 ): 33 .
Zheng X L , Liu Y J . A review of optimal control of ground source heat pump systems [J]. Fujian Tea , 2020 , 42 ( 2 ): 33 . (in Chinese)
赵雨桐 , 唐澜 , 余思言 , 等 . 绿色建筑可再生能源发展综述 [J]. 四川建材 , 2021 , 47 ( 2 ): 20 - 22,28 .
Zhao Y T , Tang N , Yu S Y , et al . Overview of renewable energy development for green buildings [J]. Sichuan Building Materials , 2021 , 47 ( 2 ): 20 - 22,28 . (in Chinese)
Xia C , Sun M , Zhang G , et al . Experimental study on geothermal heat exchangers buried in diaphragm walls [J]. Energy and Buildings , 2012 , 52 : 50 - 55 .
Sterpi D , Angelotti A , Corti D , et al . Numerical analysis of heat transfer in thermo-active diaphragm walls [M]. [ s.n. ]: Numerical Methods in Geotechnical Engineering , 2014 .
Barla M , Di Donna A . Energy tunnels: concept and design aspects [J]. Underground Space , 2018 , 3 ( 4 ): 268 - 276 .
Zeng C , Tang F , Yuan Y , et al . Thermal performance of energy diaphragm wall (EDW) adjacent to air-conditioned space from the underground-engineering perspective [J]. Geothermics , 2021 , 91 : 102044 .
Makasis N , Narsilio G A , Bidarmaghz A , et al . The importance of boundary conditions on the modelling of energy retaining walls [J]. Computers and Geotechnics , 2020 , 120 : 103399 .
Di Donna A , Cecinato F , Loveridge F , et al . Energy performance of diaphragm walls used as heat exchangers [J]. Proceedings of the Institution of Civil Engineers‑Geotechnical Engineering , 2017 , 170 ( 3 ): 232 - 245 .
Sterpi D , Coletto A , Mauri L . Investigation on the behaviour of a thermo-active diaphragm wall by thermo-mechanical analyses [J]. Geomechanics for Energy and the Environment , 2017 , 9 : 1 - 20 .
Mpq J , Delgado , De V P , et al . Influence of Mortar Joints on the Moisture Transfer in Layered Materials [J]. Diffusion and Defect Data Solid State Data , Part A Defect and Diffusion Forum, 2015 , 365 : 160 - 165 .
Wang Y , Jiang C , Liu Y , et al . The effect of heat and moisture coupling migration of ground structure without damp-proof course on the indoor floor surface temperature and humidity: Experimental study [J]. Energy and Buildings , 2018 , 158 : 580 - 594 .
Liu X , Chen Y , Ge H , et al . Numerical investigation for thermal performance of exterior walls of residential buildings with moisture transfer in hot summer and cold winter zone of China [J]. Energy & Buildings , 2015 , 93(apr.): 259 - 268 .
Xu C , Li S , Zou K . Study of heat and moisture transfer in internal and external wall insulation configurations [J]. Journal of Building Engineering , 2019 , 24 : 100724 .
Wang Y , Tian Y , Zhao Z , et al . Effect of moisture transfer on heat transfer through exterior corners of cooled buildings in hot and humid areas [J]. Journal of Building Engineering , 2021 , 43 : 103160 .
Moon H J , Ryu S H , Kim J T . The effect of moisture transportation on energy efficiency and IAQ in residential buildings [J]. Energy and Buildings , 2014 , 75 : 439 - 446 .
Luikov A V . Heat and mass transfer in capillary-porous bodies [J]. Advances in Heat Transfer , 1964 , 1 ( 1 ): 123 - 184 .
Angelotti A , Sterpi D . On the performance of energy walls by monitoring assessment and numerical modelling: a case in Italy [J]. Environmental Geotechnics , 2020 , 7 ( 4 ): 266 - 273 .
Zhou X , Yuan Y , Leng Z , et al . Numerical study on the thermal-induced mechanical behavior in deep energy diaphragm wall (EDW): The long-term soil elastoplastic effects [J]. Tunnelling and Underground Space Technology , 2023 , 132 : 104860 .
Zanden A J J V D , Schoenmakers A M E . The influence of sorption isotherms on the drying of porous materials [J]. International Journal of Heat and Mass Transfer , 1996 , 39 ( 11 ): 2319 - 2327 .
Thermal performance of buildings - Transmission and ventilation heat transfer coefficients - Calculation method: EN ISO 13789:2017 [S]. IX-CEN : European .
EN 15026 , Hygrothermal Performance of Building Components and Building Elements-Assessment of Moisture Transfer by Numerical Simulation [M]. London, UK : British Standard , 2007 : 18 - 21 .
Xu Y , Zeng Z , Sun D A . Experimental and numerical investigation on the effect of heat and moisture coupling migration of unsaturated lateritic clay for the soil thermal storage system [J]. Energy and Buildings , 2022 , 276 : 112499 .