胡逸凡,陈龙,张嘉乐等.长期循环温度下能源桩‑土热传播特性研究[J].防灾减灾工程学报,2024,44(03):697-704.
HU Yifan,CHEN Long,ZHANG Jiale,et al.Study on the Heat Propagation Characteristics of Energy Pile‑Soil under Long‑Term Cycling Temperature[J].Journal of Disaster Prevention and Mitigation Engineering,2024,44(03):697-704.
胡逸凡,陈龙,张嘉乐等.长期循环温度下能源桩‑土热传播特性研究[J].防灾减灾工程学报,2024,44(03):697-704. DOI: 10.13409/j.cnki.jdpme.20221020005.
HU Yifan,CHEN Long,ZHANG Jiale,et al.Study on the Heat Propagation Characteristics of Energy Pile‑Soil under Long‑Term Cycling Temperature[J].Journal of Disaster Prevention and Mitigation Engineering,2024,44(03):697-704. DOI: 10.13409/j.cnki.jdpme.20221020005.
开展了桩长52.5 m、桩径1.05 m的能源桩‑土热传导离心模型试验,揭示了三十个周期的冷热循环温度作用下能源桩‑土传热规律,基于ABAQUS有限元数值模拟,建立了桩周土体温度场长期数值计算模型,并将其与离心模型试验结果进行了对比验证。结果表明:各循环温度区间变化模拟值与实测值整体波动具有很好的一致性,各周期内最大相对误差为5.6%,整体误差较小,验证了模型的合理性;长期冷热循环温度作用下,能源桩整体运行效率存在降低趋势;桩端土体的温度变化滞后于桩体中部区域土体,因此在进行能源桩内管道布设时可以考虑桩端部分区域内适当加密,提高能源桩的换热性能;热循环阶段,模拟值变温区峰值高于实测变温区峰值,而在冷循环末期,模拟值较小,且距桩不同距离位置处实测值相对应的变温时间区间,相较模拟值变温区间均存在一定程度的后延,且循环周期越多时间区间后延效应越明显。
A centrifugal model test was conducted on an energy pile-soil heat conduction system
featuring a pile length of 52.5 meters and a pile diameter of 1.05 meters. This study investigated the heat transfer patterns between the energy pile and the surrounding soil over 30 cycles of cold and hot temperature. A long-term numerical model for the temperature field around the pile was established using ABAQUS finite element simulations and validated against centrifugal model test results. The following conclusions were drawn: the simulated temperature variations within each cycle closely matched the measured values
exhibiting consistent overall fluctuations and a maximum relative error of 5.6%
confirming the model's accuracy. The overall operational efficiency of the energy pile showed a declining trend under long-term thermal cycling. Temperature changes in the soil at the pile end lagged behind those in the soil at the mid-section of the pile. To enhance the heat exchange performance of the energy pile
it was suggested to increase the density of the pipeline layout within the pile end area. During the heating stage of the thermal cycling
the peak temperature in the simulated variable temperature zone was higher than the measured peak temperature. Conversely
at the end of the cold cycle
the simulated values were lower. Additionally
the measured temperature variation time intervals at different distances from the pile lagged behind the simulated time intervals. This lag effect became more pronounced with an increasing number of cycles.
Amis T , Bourne-Webb P , Davidson C , et al . The effects of heating and cooling energy piles under working load at Lambeth College,UK [C]∥ Proceedings of the 33rd Annual and 11th international Conference on Deep Foundations . New York : [s.n.] , 2008 .
Sani A K , Rao M S . Response of unsaturated soils to heating of geothermal energy pile [J]. Renewable Energy , 2020 , 147 : 2618 - 2632 .
赵海丰 , 唐荣彬 , 桂树强 , 等 . 双U型埋管能源桩桩周岩土体温度场分布特征试验研究 [J]. 土木建筑与环境工程 , 2016 , 38 ( 5 ): 157 - 163 .
Zhao H F , Tang R B , Gui S Q , et al . Experimental analysis of ground temperature distribution of double-U type energy piles [J]. Journal of Civil ,Architectural & Envirommental Engineering. 2016 , 38 ( 5 ): 157 - 163 . (in Chinese)
常虹 , 刘津男 , 孟庆宇 . 循环温度场作用下能量桩热-力学性能的试验研究 [J]. 工业建筑 , 2021 , 51 ( 1 ): 125 - 130 .
Chang H , Liu J N , Meng Q Y . Experimental study on the thermal-mechanical properties of energy piles under the action of circulating temperature field [J]. Industrial Buildings , 2021 , 51 ( 1 ): 125 - 130 . (in Chinese)
陈家威 , 张国柱 , 郭易木 , 等 . 层状地层能源管桩传热性能试验研究 [J]. 岩石力学与工程学报 , 2020 , 39 ( 增2 ): 3615 - 3626 .
Chen J W , Zhang G Z , Guo Y M , et al . Investigation on heat transfer characteristics of PHC energy piles in multi-layer strata [J]. Chinese Journal of Rock Mechanics and Engineering , 2020 , 39 ( Sup2 ): 3615 - 3626 . (in Chinese)
Pasten C , Santamarina J C . Thermally induced long-term displacement of thermoactive piles [J]. Journal of Geotechnical and Geoenvironmental Engineering , 2014 , 140 ( 5 ): 06014003 .
杨涛 , 刘律智 , 花永盛 . 冷-热循环下能量桩热-力学特性的数值模拟 [J]. 防灾减灾工程学报 , 2019 , 39 ( 4 ): 585 - 591 .
Yang T, Liu L Z, Hua Y S, Numerical simulation of thermo-mechanical behavior of energy pile subjected to cooling-heating cycle [J]. Journal of Disaster Prevention and Mitigation Engineering , 2019 , 39 ( 4 ): 585 - 591 . (in Chineses)
Loria A F R , Laloui L . Group action effects caused by various operating energy piles [J]. Géotechnique , 2018 , 68 ( 9 ): 834 - 841 .
Loria A F R , Di Donna A , Lyesse L . Thermo-mechanical analysis of energy piles through numerical and centrifuge tests [J]. Stand Alone , 2015 : 793 - 800 .
Loria A F R , Di Donna A , Laloui L . Numerical study on the suitability of centrifuge testing for capturing the thermal-induced mechanical behavior of energy piles [J]. Journal of Geotechnical and Geoenvironmental Engineering , 2015 , 141 ( 10 ): 04015042.1 - 04015042.10 .
徐健 , 任连伟 , 马艳 , 等 . 冬季工况下微型钢管桩热力响应特性数值分析 [J]. 防灾减灾工程学报 , 2019 , 39 ( 4 ): 665 - 672 .
Xu J , Ren L W , Ma Y , et al . Numerical Analysis on Thermodynamic Response Characteristics of Micro Steel Piles under Winter Conditions [J], Journal of Disaster Prevention and Mitigation Engineering , 2019 , 39 ( 4 ): 665 - 672 . (in Chinese)
Go G , Lee S , Yoon S , et al . Design of spiral coil PHC energy pile considering effective borehole thermal resistance and groundwater advection effects [J]. Applied Energy , 2014 , 125 : 165 - 178 .
曾和义 , 方肇洪 . 双U型埋管地热换热器的传热模型 [J]. 山东建筑工程学院学报 , 2003 ( 1 ): 11 - 17 .
Zeng H Y , Fang Z H . A heat transfer model for double U tube geothermal heat exchangers [J]. Journal of Shanxi University of Architecture and Engineering , 2003 ( 1 ): 11 - 17 . (in Chinese)
Hamada Y , Saitoh H , Nakamura M , et al . Field performance of an energy pile system for space heating [J]. Energy & Buildings , 2006 , 39 ( 5 ): 517 - 524 .
闫振国 , 张正威 , 杨军 . 考虑桩身热容的能量桩传热性能分析 [J]. 防灾减灾工程学报 , 2019 , 39 ( 4 ): 599 - 606 .
Yan Z G , Zhang Z J , Yang J . Analysis of heat transfer performance of energr pile considering heat capacity of pile body [J]. Journal of Disaster Prevention and Mitigation Engineering , 2019 , 39 ( 4 ): 599 - 606 . (in Chinese)
王哲 , 刘耶军 , 张正威 , 等 . 能源桩全生命周期热响应半径简化计算方法 [J]. 中南大学学报(自然科学版) , 2020 , 51 ( 2 ): 514 - 522 .
Wang Z , Liu Y J , Zhang Z W , et al . Simplified calculation method of thermal response radius of energy pile in its whole life cycle [J]. Journal of Central South University (Science and Technology) , 2020 , 51 ( 2 ): 514 - 522 . (in Chinese)
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
苏公网安备32010202012147号