1.中国地震局工程力学研究所,河北 三河 065201
2.中国地震局地震工程与工程振动重点实验室,黑龙江 哈尔滨 150080
3.中国建筑标准设计研究院有限公司,北京 100048
冯云幸(1993—),女,硕士研究生。主要从事吊顶的数值模拟与地震易损性研究。E‑mail: fyxokk@163.com
曲哲(1983—),男,研究员,博士。主要从事建筑抗震、减震与隔震技术研究。E‑mail: quz@iem.ac.cn
收稿:2021-11-11,
修回:2021-11-24,
纸质出版:2022-12-28
移动端阅览
冯云幸,曲哲,李戚齐.吊顶地震时程反应分析的二维简化模型[J].防灾减灾工程学报,2022,42(06):1222-1227.
FENG Yunxing,QU Zhe,LI Qiqi.A Two‑dimensional Simplified Model for Seismic Response History Analysis of Suspended Ceilings[J].Journal of Disaster Prevention and Mitigation Engineering,2022,42(06):1222-1227.
冯云幸,曲哲,李戚齐.吊顶地震时程反应分析的二维简化模型[J].防灾减灾工程学报,2022,42(06):1222-1227. DOI: 10.13409/j.cnki.jdpme.20211111020.
FENG Yunxing,QU Zhe,LI Qiqi.A Two‑dimensional Simplified Model for Seismic Response History Analysis of Suspended Ceilings[J].Journal of Disaster Prevention and Mitigation Engineering,2022,42(06):1222-1227. DOI: 10.13409/j.cnki.jdpme.20211111020.
吊顶是由各种轻钢龙骨、吊顶板、吊杆等构件拼装组成的松散的非连续体系,其地震反应的数值模拟尚缺乏研究。介绍一种用于吊顶地震反应分析的二维简化模型,能够模拟吊顶在沿主龙骨方向的水平地震作用和竖向地震作用下的动力反应,且能够考虑吊顶板与龙骨之间的摩擦、滑移、碰撞等因素的影响。利用该模型在OpenSees中模拟了由4块吊顶板组成的基本吊顶单元的双向加载振动台试验。通过对比试验和数值模拟得到的吊顶加速度反应的时程和傅里叶谱以及坠板率,验证了该二维简化模型的合理性。进一步,利用该模型考察了吊顶坠板率的频率相关性。结果表明,吊顶的坠板率不仅仅取决于楼面峰值加速度的大小,而是表现出显著的频率相关性。
The suspended ceiling is a flexible system composed of loosely connected light-gauge-steel runners, panels, hanger rods, etc. There is still a lack of research on the numerical simulation of its seismic response. This paper introduces a two-dimensional simplified model for response history analysis of suspended ceilings under combined horizontal and vertical earthquake excitation along the main keel direction. The friction, sliding and pounding between the ceiling panels and the runners are also included in the model. The model is implemented in OpenSees and is calibrated by a shake table test on a minimum suspended ceiling unit composed of four panels and a single hanger rod. The rationality of the presented model is verified by comparing the acceleration response time history, Fourier spectrum and the rate of the fallen panels of the suspended ceiling obtained by experiments and numerical simulation. The model is further used to identify the engineering demand parameters that correlate with the extent of seismic damage in the suspended ceiling. The results show that the rate of the fallen panels not only depends on the peak floor acceleration, but also shows significant frequency-dependency.
李戚齐 . 明架矿棉板吊顶的地震损伤特征研究 [D]. 哈尔滨 : 中国地震局工程力学研究所 , 2019 .
Li Q Q . Study on the seismic damage characteristics of suspended ceilings of exposed runners and mineral wool boards [D]. Harbin : Institute of Engineering Mechanics , 2019 . (in Chinese)
李戚齐 , 曲哲 , 解全才 , 等 . 我国公共建筑中吊顶的震害特征及其易损性分析 [J]. 工程力学 , 2019 , 36 ( 7 ): 207 ‑ 215 .
Li Q Q , Qu Z , Xie Q C , et al . Seismic damage characteristics and fragility of suspended ceilings in Chinese public buildings [J]. Engineering Mechanics , 2019 , 36 ( 7 ): 207 ‑ 215 . (in Chinese)
国家建筑标准设计图集《内装修‑室内吊顶》:12J 502‑2 [S]. 北京 : 中国计划出版社 , 2013 .
Soroushian S , Rahmanishamsi E , Ryu K P , et al . Experimental fragility analysis of suspension ceiling systems [J]. Earthquake Spectra , 2016 , 32 ( 2 ): 881 ‑ 908 .
Soroushian S , Rahmanishamsi E , Jenkins C , et al . Fragility analysis of suspended ceiling systems in a full‑scale experiment [J]. Journal of Structural Engineering , 2019 , 145 ( 4 ): 04019005 .
Ryan K L , Soroushian S , Maragakis M , et al . Seismic simulation of an integrated ceiling‑partition wall‑piping system at E‑Defense.I: Three‑dimensional structural response and base isolation [J]. Journal of Structural Engineering , 2016 , 142 ( 2 ): 04015130 .
Soroushian S , Maragakis M , Ryan K L , et al . Seismic simulation of an integrated ceiling‑partition wall‑piping system at E‑Defense.II: Evaluation of nonstructural damage and fragilities [J]. Journal of Structural Engineering , 2016 , 142 ( 2 ): 04015131 .
Lu Y , Mosqueda G , Han Q H , et al . Shaking table tests examining seismic response of suspended ceilings attached to large‑span spatial structures [J]. Journal of Structural Engineering , 2018 , 144 ( 9 ): 04018152 .
Brandolese S , Fiorin L , Scotta R . Seismic demand and capacity assessment of suspended ceiling systems [J]. Engineering Structures , 2019 , 193 : 219 ‑ 237 .
Ryu K P , Reinhorn A M . Experimental study of large area suspended ceilings [J]. Journal of Earthquake Engineering , 2019 , 23 ( 6 ): 1001 ‑ 1032 .
韩庆华 , 赵一峰 , 卢燕 . 吊顶系统自振特性分析及试验研究 [J]. 建筑结构学报 , 2018 , 39 ( 7 ): 95 ‑ 103 .
Han Q H , Zhao Y F , Lu Y . Natural vibration characteristic analysis and experimental research of suspended ceiling systems [J]. Journal of Building Structures , 2018 , 39 ( 7 ): 95 ‑ 103 . (in Chinese)
Zaghi A E , Soroushian S , Heiser A E , et al . Development and validation of a numerical model for suspended‑ceiling systems with acoustic tiles [J]. Journal of Architectural Engineering , 2016 , 22 ( 3 ): 04016008 .
Soroushian S , Maragakis M , Zaghi A E , et al . Numerical simulation of integrated suspended ceiling-sprinkler systems [J]. Structures Congress , 2015 : 1879 - 1890 . doi: 10.1061/9780784479117.162 http://dx.doi.org/10.1061/9780784479117.162 .
Soroushian S , Maragakis M , Jenkins C . Axial capacity evaluation for typical suspended ceiling joints [J]. Earthquake Spectra , 2016 , 32 ( 1 ): 547 ‑ 565 .
Soroushian S , Maragakis M , Jenkins C . Capacity evaluation of suspended ceiling‑perimeter attachments [J]. Journal of Structural Engineering , 2016 , 142 ( 2 ): 04015124 .
Fiorin L , Brandolese S , Scotta R . Experimental and numerical assessment of suspended ceiling joints [J]. Bulletin of Earthquake Engineering , 2021 , 19 : 919 ‑ 962 .
A SCE/SEI 41‑06 . Seismic rehabilitation of existing buildings [S]. American Society of Civil Engineers, Reston, VA, 2006 .
0
浏览量
0
下载量
2
CSCD
关联资源
相关文章
相关作者
相关机构
苏公网安备32010202012147号