借助自行研制的地源热泵系统热湿迁移实验平台
开展了冬季制热工况下地源热泵系统的运行实验
探讨并分析了地埋管热交换性能及周围土壤温度场的变化规律。实验结果表明:竖直地埋管的换热性能明显优于水平埋管
更有利于地热能的开发利用;地表3.0m以内仍处在大气影响范围之内
该处土壤温度变化受地埋管换热器与土壤间的热交换、周围气候环境变化共同作用的影响;水平地埋管附近土壤温度降低的幅度与距离地埋管的远近及方向有关
其温度降低幅度随着距离的增加而减小
且热量在土壤中的热传导作用因方向而异。
The operation experiment of ground source heat pump system in winter heating condition was carried out by means of thermal and wet migration experiment platform
which was developed by authors. Besides
the changes of heat exchange performance and temperature field around the soil were discussed and analyzed. The results of test indicate that the heat transfer performance of the vertical pipe is obviously better than that of the horizontal pipe
which is more favorable to the development and utilization of geothermal energy. The surface temperature within 3. Om is still influenced by the atmosphere
where the soil temperature is changed by the ground heat exchanger and the heat exchange between the soil
the surrounding climate and environmental changes under the impact of the interaction. The decrease of soil temperature near the horizontal buried pipe is related to the distance and direction of the buried pipe
and the temperature decreases with the increase of the distance
and the heat conduction in the soil has the characteristics of anisotropy.
岩溶区地源热泵系统土壤热湿迁移实验平台研制 [J]. 曾召田,徐云山,赵艳林,吕海波,唐双慧. 广西大学学报(自然科学版) . 2016(01)
地下水渗流对竖埋管换热器传热影响的数值模拟 [J]. 曾召田,吕海波,赵艳林,葛若东. 太阳能学报 . 2015(12)
中国大陆干热岩地热资源潜力评估 [J]. 汪集旸,胡圣标,庞忠和,何丽娟,赵平,朱传庆,饶松,唐晓音,孔彦龙,罗璐,李卫卫. 科技导报 . 2012(32)
中国能源政策可持续性评价与发展路径选择 [J]. 沈镭,刘立涛. 资源科学 . 2009(08)
我国能源节约战略研究 [J]. 郎一环,沈镭. 中国人口.资源与环境 . 2006(02)
地源热泵及地下蓄能系统的实验研究 [J]. 王勇,刘宪英,付祥钊. 暖通空调 . 2003(05)
竖直埋管地热换热器的稳态温度场分析 [J]. 曾和义,刁乃仁,方肇洪. 山东建筑工程学院学报 . 2002(01)
Numerical modeling of a ground source heat pump: The Bolu case [J] . Unal Camdali,Murat Bulut,Nedim Sozbir. Renewable Energy . 2015
General review of ground-source heat pump systems for heating and cooling of buildings [J] . Ioan Sarbu,Calin Sebarchievici. Energy & Buildings . 2014
Greenhouse gas emission savings of ground source heat pump systems in Europe: A review [J] . Peter Bayer,Dominik Saner,Stephan Bolay,Ladislaus Rybach,Philipp Blum. Renewable and Sustainable Energy Reviews . 2011 (2)
Experimental study of vertical ground-source heat pump performance evaluation for cold climate in Turkey [J] . Omer Ozyurt,Dundar Arif Ekinci. Applied Energy . 2010 (4)
Experimental performance evaluation of a closed‐loop vertical ground source heat pump in the heating mode using energy analysis method [J] . Yusuf AliKara. Int. J. Energy Res. . 2007 (15)
0
浏览量
61
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
苏公网安备32010202012147号