The practical building structure subjected to combined loading and fire is successive process from normal service to subjection to fire and strengthening
which includes the full-range loading with ambient temperature
heating
cooling and post-fire phases
and the full-range fire with heating and cooling.Based on the whole process loading and fire
a finite element analysis(FEA)model for steel reinforced concrete column(SRCC)under the full-range fire were established and validated by the corresponding tests.After that
based on the verified FEA model
the temperature distributions
the axial deformations and the internal force redistribution were analyzed.This is helpful to investigate the residual load bearing capacities of the SRC columns.The results show that without the combined loading and fire including heating and cooling phases
the post-fire residual load bearing capacities of the SRC columns and the corresponding peak displacement are non-conservative
and the internal forces redistribute in the section occurs under the full-range loading and fire.
Concrete filled steel tube stub columns under combined temperature and loading [J] . Tian-Yi Song,Lin-Hai Han,Hong-Xia Yu. Journal of Constructional Steel Research . 2009 (3)
Effects of heating and loading histories on post-fire cooling behaviour of concrete-filled steel tubular columns [J] . Hua Yang,Lin-Hai Han,Yong-Chang Wang. Journal of Constructional Steel Research . 2007 (5)